omron — 20S025 STC MxS510CXP6 Spec Manual EN (EN)

No.20S025-02 9 IO Function This chapter describes IO functions. In this chapter, the IO Port places as “Line”. The follow chart details relationship of Line and IO Port. GenICam Parameters 9.1 Input Port Function This function sets the input on Line Mode, then assigns Line as input. The following functions can be assigned as input. When select “input” assign port at Trigger Source, input signal can be assigned as Trigger. The input signal can be switched to Active-Low (LineInverter: true) or Active-High (LineInverter: false). (*) When the Line polarity changing by Line Inverter, active polarity of input trigger signal is changed. This function monitors the signal status on input Line.

The High level (LineStatus: true) or Low level (LineStatus false) status can be seen through software. STC-MBS510CXP6 / STC-MCS510CXP6 Product Specifications and User’s Guide 38/49 IO Port Pin No. Line number 2 Line3 3 Line2 4 Line1 5 Line0 LineSelector IEnumeration Type Select Line LineMode IEnumeration Type Switch input / output direction for Line that was selected at LineSelector. Input: set as input, Output: set as output LineInverter IBoolean Type Switch polarity inversion ON / OFF for Line that was selected at LineSelector. False: polarity inversion Off (Active-High), True:

polarity inversion On (Active-Low) LineStatus IBoolean Type Line status (High / Low) LineSource IEnumeration Type Set function for Line that was selected at LineSelector UserOutputSelector IEnumeration Type Select UserOutput UserOutputValue IBoolean Type Switch voltage level of UserOutput that was selected at UserOutputSelector False: Low voltage level, True: High voltage level