No.20S025-02 High or low level signal that was configured on software is output. Setting Procedure Selects LineN (N: any number from 0, 1 or 2) 1) Sets the UserOutputN (N is Line number) as LineSource 2) Selects UserOutputN (N is same as selected Line number on UserOutput) on UserOutputSelector 3) Sets the value (True: High level, False: Low level) on UserOutputValue Monitor the status on output port. Monitor the output voltage level High (LineStatus: true) or Low (LineStatus: false) through software. Some selectable functions can be modified in order to add to duration or pulse width on Line Source. The configurable parameters are shown in chart below.
Please refer to LineSource for applicable functions of parameters. GenICam Parameters STC-MBS510CXP6 / STC-MCS510CXP6 Product Specifications and User’s Guide 42/49 TriggerOutDelay IInteger Type Trigger Out Delay Time Range: 0 to 262,143 μseconds, Default: 0 μsecond TriggerOutOnTime IInteger Type Trigger Out On Time Range: 4 to 262,143 μseconds, Default: 32 μseconds StrobeOutDelay IInteger Type Strobe Out Delay Time Range: 0 to 262,143 μseconds, Default: 30 μseconds StrobeOutOnTime IInteger Type Strobe Out On Time Range: 4 to 262,143 μseconds, Default: 32 μseconds