Siemens — Software Compatibility

Installation The SmartLinx module is either shipped already installed in the Siemens Milltronics instrument or separately for on-site installation. Refer to the manual of your Siemens Milltronics instrument for details on module location and physical installation. Compatibility For the SmartLinx PROFIBUS card there are different hardware and software configurations available depending on the equipment used. Software Compatibility If a device is SmartLinx ready, it will work with the correct SmartLinx card for that device. However, if the firmware version is a lower number than the one listed below, the Map Element Selection Parameter (P762) will not be available.

Also, for the BW500, BW500/L, and SF500, the read block will be a smaller size. Installation Retrofits If you are replacing an older SmartLinx device with a new SmartLinx device, and you are using any product other than the BW500, BW500/L, or SF500, then you can use the default values for P762. If you are replacing a BW500, BW500/L, or SF500 with a new device, then set P762 primary index 15 = 0, and P762 primary index 16 = 0. 7ML19981AQ03 SmartLinx PROFIBUS DP – INSTRUCTION MANUAL Page 5 Product Software Rev. Product Software Rev.

AiRanger XPL Plus / SITRANS LU 10 5.23 Milltronics BW500/L 3.13 AiRanger DPL Plus / SITRANS LU 02 Milltronics BW500 3.05 Milltronics SF500 AiRanger SPL / SITRANS LU 01 MultiRanger 100 1.04 InterRanger DPS 300 MultiRanger 200 1.03 HydroRanger 200 EnviroRanger ERS 500 5.06