MAIN SCREEN The main screen appears after the unit is turned on and remains in place until the "MENU" key is pressed to change to the menu selection.. Main screen view SY field : The upper field of the monitor shows warning and indicator symbols, up to maximum 4 symbols at the same time. If more than 4 symbols must be shown, then every 10 seconds, the symbols move to the left by one symbol. The following list shows all symbols which can appear in this field. EC field: The EC window displays any applicable error codes for any electrical errors in the excavator electronics, (line errors, sensor errors, ...). Max. 7 error codes can be displayed at the same time .
If more than 7 errors occur, an arrow next to the error code window points to additional error codes on the list. Press the arrow key to move the error code window in the selected direction on the error code list. For detailed error codes list, refer next pages. INF field: The INF field on the right hand side of the main screen displays temporary information, also in graphic form. If more than 3 symbols must be shown, then every 10 seconds, the symbols move to the left by one symbol. Displays are shown as graphics or text and inform about specific operating conditions (such as actuated flow reduction, emergency operation of Diesel engine or hydraulic pumps, ). 3.8