OM6007 8/00 Optional Equipment - Section 6 Payload Meter II Page 6-19 DISPLAY OF FAULT CODES Condition of the Engine Oil Pressure signal. The panel will display “ :C3:XX ” for 3 seconds, then indicate: 1. Press and hold the MODE switch until "Cd:dP" is displayed. 2. Press the MODE switch once. The display will show: C3:oo ” Engine is running. ” Engine is not running. 3. Press the MODE switch once. The display will show: Condition of Alternator ’R’ terminal signal. The panel will display “ C4:XX ” for 3 seconds, then indicate: 4. Press the TOTAL/SFT switch. C4:oo ” Engine is running. If there are no faults or warnings, the display will show for 6 seconds. ” Engine is not running.
Condition of the Spare Analog Input 1 signal. If there are current faults or warnings, the codes will be displayed in order of their priority, the highest priority first. Each code will flash for 6 seconds. The panel will display “ C5:XX ” for 3 seconds with XX: as an input signal (V). Condition of the Spare Analog Input 2 signal. 5. After the current codes have been displayed, past history codes that have been reset will be dis- played. Each code will flash for 3 seconds. The panel will display “ C6:XX ” for 3 seconds with XX: as an input signal (V). If there are no history codes or after all history codes have been shown , the display will show for 3 seconds:
Condition of the Spare Digital Input 1 signal. The panel will display “ C7:XX ” for 3 seconds, then: C7:oo ” High. The system will then proceed to the following displays: Refer to Page 22 for details. ” Low. Condition of the shift selector on mechanical trucks or brake lock on electric trucks. Condition of the Spare Digital Input 2 signal. The panel will display “ C8:XX ” for 3 seconds, then: The panel will display: “ C1:XX ” for 3 seconds, then indicate: C8:oo ” High. Mechanical trucks ” Low. C1:oo ” Shift selector is in "N". 4. Press the TOTAL/SFT switch to view faults again or press the MODE switch to return to normal operation. ” Shift selector is not in "N’.
Electric trucks ” Brake lock is off. C1:oo ” Brake lock is on. Condition of the Body Up Switch signal. The panel will display: “ C2:XX ” for 3 seconds, then indicate: C2:oo ” Body up switch is in up position. ” Body up switch is in down position.