3. OPERATION 3.12 ACCUMULATOR Accumulator The accumulator (Fig. 3.11A) stores system pressure until it is required to activate the electric auxiliary. The key must be placed in the “ON” position to operate the electric auxiliary (engine not running). The electric auxiliary and stored pressure in the accumulator can be used to release the hydraulic pressure in the auxiliary hydraulic system. This is accomplished by cycling the momentary switch on the LH control a couple of times (see Fig. 3.11B). Once this pressure is released the operator can disconnect the couplers to the attachment from the loader.. C3896 Fig. 3.11A High Pressure Accumulator. NEVER use oxygen or shop air. 1.
Do not operate without sufficient dry nitrogen gas pressure. 2. Release all pressure prior to servicing or disassembly. 3. Read all service and operator instructions prior to use. 4. Do not operate beyond stamped maximum working pressure. 5. Do not weld or modify this unit in any way. CAUTION 35 AUXILIARY HYDRAULIC CONTROL Momentary Switch ROPS SIDE SEAT SIDE C3015 Fig. 3.11B C3015 Fig. 3.11B