Starter/Starter 12. Test for short circuited windings using a growler. Put armature in growler and hold a hacksaw blade above each slot while slowly rotating armature. If coil is shorted, the blade will vibrate on the slot. NOTE: A short circuit most often occurs because of copper dust or filings between two commutator segments. M17166 -UN-24APR89 13. If test indicates short circuited windings, clean the commutator of dust and filings. Check the armature again. If the test still indicates a short circuit, replace the armature. M98,2060K,21 -19-05NOV85 ASSEMBLE BENDIX DRIVE STARTER 1. Apply a generous film of silicone base grease, such as GE Versilube 322-L or equivalent, to the worm gear. 2.
Apply a thin film of grease to bearing surfaces (A). M37114 -UN-25JAN90 M98,2060K,22 -19-05NOV85 60 10 CTM2 (19APR90) 60-10 16, 18, 20 & 24HP Onan Engines AllTractorManuals.com 130495