hitachi — REMOVE AND INSTALL PILOT VALVE

UPPERSTRUCTURE / Pilot Valve 7. Remove bolt (14) and screw (17). Remove covers (15, 16) from bracket (9). : 10 mm 8. Remove clip bands (20) (2 used). Disconnect the connector of harness (21). 9. Loosen lock nut (19). Remove the lever (18) assembly from pilot valve (22). 15 14 16 17 W1JB-02-07-011 9 19 18 20 : 19 mm, 32 mm 10. Remove hoses (23) (6 used) from pilot valve (22). Attach an identification tag onto the removed hoses for assembling. Cap the open ends. 21 W1JB-02-07-005 22 22 : 19 mm W1JB-02-07-006 23 W2-7-3