MAINTENANCE MAINTENANCE PROCEDURE Install Air Cleaner Element 4 1. Open the battery room door on the left side of the machine, remove clips (2) at 3 places, then take out cover (3). 2. Remove outer element (4). Do not remove inner element (5) at this time, however. NOTICE When cleaning cover (3), do not remove evacuator valve (6). 3. Clean the inside of the air cleaner body and the cover (3). 4. Remove inner element (5), then install a new inner element immediately. When installing the cover (3), check O-ring (7) and replace it if there are any scratches or damage. 5. Set the cleaned outer element in position, then secure cover (3) with mounting clips (2). 6.
Replace the seal attached to cover (3) with new one. 4-23 CAUTION