Komatsu — Clean element in air conditioner fresh air filter

4.8 Service procedure Maintenance Every 100 hours service 4.8.5 Every 100 hours service Maintenance for every 50 hours service should be carried out at the same time. Lubricate rear axle pivot pin (2 places) 1. Using a grease pump, pump in grease through the grease fittings marked by the arrows. 2. After greasing, wipe off any old grease that was pushed out. GK015019 Clean element in air conditioner fresh air filter If compressed air is used, there is danger that dirt may fly and cause personal injury. Always wear safety glasses, dust mask, and other protec- tive equipment. If the air conditioner has been used, the air filter should be cleaned.

Stop the air conditioner before cleaning the element. 1. Open cover (1). 2. Remove bracket (2) and filter (3) as one unit. 3. Direct dry compressed air (less than 0.69 MPa (7 kgf/cmІ, 99.4 PSI)) to the element from inside along its folds, then direct it from outside along its folds and again from inside. 3 4. When installing, fit filter (3) into bracket (2), then install. GK032265 1 2 WA150-5H – VEAM934100 4-41 WARNING WARNING