Komatsu — STARTING WITH BOOSTER CABLES

. SAFETY PRECAUTIONS FOR OPERATION 2 - 32 STARTING WITH BOOSTER CABLES If any mistake is m cables follows operation with tw o workers (on e worke r sitting in th e operator's seat and the oth er working with the ba When starting f achin machines to tou When connectin cables OFF position f or both the normal machine an d problem machine. There i s a hazard that the ma chine will mo ve when the power is connec ted. Be s ure to conne ct the positive (+) cab le first when i nstalling the booster cables. Disconnect the negati ve (-) cable (g round side) first when remov When removing ing them.

the booster cables, be careful not to let the booster cable cli ps touch each other o r to let the clip s touch the machine. Always wear saf ety glasses and rubbe r gloves when starting the engine with boos ter cables. When connectin g a normal machine to a problem m achine with booster cables, always use a normal machine with the same e. battery voltage a s the problem machin For details of the starting procedure wh en using boo ster cables, see "STARTING ENGINE WITH BO OSTER CABLE (PAGE 3-97)" in the OP ERATION section.