X058 X038 SHIELD905 SH_THC01-A TWIST_THC01-A HVCGND-I BK 0.35 FLRY 1126.0 HVAC Case B,P,J,W X050 X051 X052 X053 X054 X055 X056 X057 X058 Body Controller Right A,D,J,W X030 X031 X032 X033 X034 X035 X036 X037 X038 Body Controller Left X058-19 Vref Output HVAC Shared 5V X058-8 Half-Bridge HVAC Right Bleed CW X058-5 Analog In HVAC Right Bleed Duct Position X058-9 Half-Bridge HVAC Right Bleed CCW X058-23 Half-Bridge HVAC Lower Mode CW X058-2 Analog In HVAC Lower Mode Duct Position X058-24 Half-Bridge HVAC Lower Mode CCW X058-27 Half-Bridge HVAC Intake CW X058-4 Analog In HVAC Intake Duct Position X058-28 Half-Bridge HVAC Intake CCW X058-10 Half-Bridge HVAC Left Bleed CW X058-6 Analog In HVAC Left Bleed Duct Position X058-11 Half-Bridge HVAC Left Bleed CCW X058-25 Half-Bridge HVAC Upper Mode CW X058-3 Analog In HVAC Upper Duct Position X058-26 Half-Bridge HVAC Upper Mode CCW X058-13 Analog In HVAC Left Vent Duct Temp X058-16 Analog In HVAC Right Vent Duct Temp X058-17 Analog In HVAC Evaporator Temp X058-20 Ground Return HVAC Shared Ground Return HVAC Blower Motor Phase A X038-2 Half-Bridge HVAC Blower Motor Phase B X038-4 Half-Bridge HVAC Blower Motor Phase C X038-1 Half-Bridge HVAC Blower Motor Ground Shield X038-3 Ground Return Body Controller Right B,P,J,W X050 X051 X052 X053 X054 X055 X056 X057 X058 Z1-HVC005V HVAC Case X058-19 Vref Output HVC005V-F RD 0.35 FLRY HVAC CASE X544 X547 X548 X549 X550 X551 X552 X553 X554 X555 X556 HVAC Shared 5V 993.0 HVAC Case _ HVC005V-B RD 0.35 FLRY X552-4 Power In 397.0 HVAC Case Vref Potentiometer (+5V) X058-8 Half-Bridge HVC017-A BU 0.35 FLRY X552-3 Analog In HVAC Right Bleed CW 1236.0 HVAC Case CW Input X058-5 Analog In HVC019-A WH 0.35 FLRY X552-5 Analog Out HVAC Right Bleed Duct Position 1236.0 HVAC Case Potentiometer Feedback X058-9 Half-Bridge HVC018-A PK 0.35 FLRY X552-7 Analog In HVAC Right Bleed CCW 1236.0 HVAC Case CCW Input HVCGND-B BK 0.35 FLRY X552-6 Ground Return 110.0 HVAC Case X552 Vref Return Actuator (GND) HVC005V-D RD 0.35 FLRY X553-3 Power In 700.0 HVAC Case Vref Potentiometer (+5V) X058-23 Half-Bridge HVC004-A VT/GN 0.35 FLRY X553-5 Analog In HVAC Lower Mode CW 1693.0 HVAC Case CW Input X058-2 Analog In HVC006-A BU 0.35 FLRY X553-2 Analog Out HVAC Lower Mode Duct Position 1693.0 HVAC Case Potentiometer Feedback X058-24 Half-Bridge HVC005-A RD 0.35 FLRY X553-6 Analog In HVAC Lower Mode CCW 1693.0 HVAC Case CCW Input HVCGND-H BK 0.35 FLRY X553-1 Ground Return 987.0 HVAC Case X553 Vref Return Actuator (GND) HVC005V-A RD 0.35 FLRY X554-3 Power In 205.0 HVAC Case Vref Potentiometer (+5V) X058-27 Half-Bridge HVC001-A BU 0.35 FLRY X554-5 Analog In HVAC Intake CW 1198.0 HVAC Case CW Input X058-4 Analog In HVC003-A WH 0.35 FLRY X554-2 Analog Out HVAC Intake Duct Position 1198.0 HVAC Case Potentiometer Feedback X058-28 Half-Bridge HVC002-A VT/GN 0.35 FLRY X554-6 Analog In HVAC Intake CCW 1198.0 HVAC Case CCW Input HVCGND-C BK 0.35 FLRY X554-1 Ground Return 492.0 HVAC Case X554 Vref Return Actuator (GND) HVC005V-E RD 0.35 FLRY X555-4 Power In 647.0 HVAC Case Vref Potentiometer (+5V) X058-10 Half-Bridge HVC010-A BU 0.35 FLRY X555-3 Analog In HVAC Left Bleed CW 1486.0 HVAC Case CW Input X058-6 Analog In HVC012-A WH 0.35 FLRY X555-5 Analog Out HVAC Left Bleed Duct Position 1486.0 HVAC Case Potentiometer Feedback X058-11 Half-Bridge HVC011-A PK 0.35 FLRY X555-7 Analog In HVAC Left Bleed CCW 1486.0 HVAC Case CCW Input HVCGND-A BK 0.35 FLRY X555-6 Ground Return 360.0 HVAC Case X555 Vref Return Actuator (GND) HVC005V-C RD 0.35 FLRY X556-3 Power In 445.0 HVAC Case Vref Potentiometer (+5V) X058-25 Half-Bridge HVC007-A VT/GN 0.35 FLRY X556-5 Analog In HVAC Upper Mode CW 1438.0 HVAC Case CW Input X058-3 Analog In HVC009-A VT/GN 0.35 FLRY X556-2 Analog Out HVAC Upper Duct Position 1438.0 HVAC Case Potentiometer Feedback X058-26 Half-Bridge HVC008-A PK 0.35 FLRY X556-6 Analog In HVAC Upper Mode CCW 1438.0 HVAC Case CCW Input HVCGND-D BK 0.35 FLRY X556-1 Ground Return 732.0 HVAC Case X556 Vref Return Actuator (GND) X058-13 Analog In HVC516-A VT/GN 0.35 FLRY X547-1 Analog Out HVAC Left Vent Duct Temp 1651.0 HVAC Case Signal HVCGND-E BK 0.35 FLRY X547-2 Ground Return 525.0 HVAC Case X547 Vref Return (GND) X058-16 Analog In HVC6137-A BK 0.35 FLRY X550-1 Analog Out HVAC Right Vent Duct Temp 1471.0 HVAC Case Signal HVCGND-F BK 0.35 FLRY X550-2 Ground Return 765.0 HVAC Case X550 Vref Return (GND) X058-17 Analog In HVC517-A WH 0.35 FLRY X551-1 Analog Out HVAC Evaporator Temp 1736.0 HVAC Case Signal X058-20 Ground Return HVCGND-I BK 0.35 FLRY HVCGND-G BK 0.35 FLRY X551-2 Ground Return HVAC Shared Ground Return 1126.0 HVAC Case 610.0 HVAC Case X551 Vref Return (GND) X058 Z2-HVCGND THE INFORMATION CONTAINED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF TESLA MOTORS.
THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED AS THE DIRECT OR INDIRECT BASIS FOR THE DEVELOPMENT, MANUFACTURE, OR SALE OF PROCESSES OR PRODUCTS WITHOUT THE EXPRESSD WRITTEN CONSENT OF TESLA MOTORS.
DRAWN CHECKED APPROVED Body Controller Left Blower Motor A,D,J,W X030 X031 X032 X033 X034 X035 X036 X037 X038 J SH THC01-A SH THC01-A _ X038-2 Half-Bridge _ THC01-A RD 4.00 FLRB X536-1 Half-Bridge MATERIAL FINISHING SCALE HVAC Blower Motor Phase A 1079.047107 1067960-XX-E, 1117960-XX-A (J) Phase 1 (U) TWIST THC01-A TWIST THC01-A AS SPECIFIED AS SPECIFIED NONE _ _ X038-4 Half-Bridge THC02-A BK 4.00 FLRB X536-2 Half-Bridge HVAC Blower Motor Phase B 1079.047107 1067960-XX-E, 1117960-XX-A (J) Phase 2 (V) PART NAME X038-1 Half-Bridge THC03-A OG 4.00 FLRB X536-4 Half-Bridge HVAC Case Subassembly HVAC Blower Motor Phase C 1079.047107 1067960-XX-E, 1117960-XX-A (J) Phase 3 (W) X038-3 Ground Return SHIELD905 SHIELD905 X536-3 Ground Return PART NUMBER REV SHEET SIZE HVAC Blower Motor Ground Shield GND Shielding if Needed X038 X536 2 27 45 A0 OF THE INFORMATION CONTAINED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF TESLA MOTORS.
THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED AS THE DIRECT OR INDIRECT BASIS FOR THE DEVELOPMENT, MANUFACTURE, OR SALE OF PROCESSES OR PRODUCTS WITHOUT THE EXPRESSD WRITTEN CONSENT OF TESLA MOTORS.
DRAWN CHECKED APPROVED MATERIAL AS SPECIFIED FINISHING AS SPECIFIED SCALE NONE PART NAME HVAC Case Subassembly PART NUMBER REV 2 SHEET 27 45 OF SIZE A0 1236.0 HVAC Case HVC019-A WH 0.35 FLRY 1236.0 HVAC Case HVC018-A PK 0.35 FLRY 1236.0 HVAC Case HVCGND-B BK 0.35 FLRY 110.0 HVAC Case HVC004-A VT/GN 0.35 FLRY 110.0 HVAC Case HVC004-A VT/GN 0.35 FLRY 1693.0 HVAC Case HVC006-A BU 0.35 FLRY 1693.0 HVAC Case HVC005-A RD 0.35 FLRY 1693.0 HVAC Case HVCGND-H BK 0.35 FLRY 987.0 HVAC Case HVC001-A BU 0.35 FLRY 987.0 HVAC Case HVC001-A BU 0.35 FLRY 1198.0 HVAC Case HVC003-A WH 0.35 FLRY 1198.0 HVAC Case HVC002-A VT/GN 0.35 FLRY 1198.0 HVAC Case HVCGND-C BK 0.35 FLRY 492.0 HVAC Case HVC010-A BU 0.35 FLRY 492.0 HVAC Case HVC010-A BU 0.35 FLRY 1486.0 HVAC Case HVC012-A WH 0.35 FLRY 1486.0 HVAC Case HVC011-A PK 0.35 FLRY 1438.0 HVAC Case HVC009-A VT/GN 0.35 FLRY 1438.0 HVAC Case HVC008-A PK 0.35 FLRY HVCGND-I BK 0.35 FLRY 1736.0 HVAC Case HVCGND-G BK 0.35 FLRY 1079.047107 1067960-XX-E, 1117960-XX-A (J) TWIST THC01-A TWIST THC01-A _ _ THC02-A BK 4.00 FLRB 1079.047107 1067960-XX-E, 1117960-XX-A (J) THC03-A OG 4.00 FLRB