omron — Mounting Clearances

Chapter 4: eMotionBlox-40M 19148-000 Rev. E Cobra 450, 500, and 650 User's Guide 43 Key Meaning Key Meaning A M4 X 7 mm DP BLIND STUDS SPCD AS SHOWN, 20x B Note: 112 mm clearance required in front of unit to remove AIB from box enclosure. unting Clearances NOTE: The mounting of the eMB-40M and all terminations at the eMB-40M must be performed in accordance with all local and national standards. The following space must be left around the eMB-40M for proper cooling: B 50 A STATUS EXPIO BRAKE 50 50 C 2DI4NCV XSYSTEM GND1AC ENET ENET Servo Ø XIO XBELTIO 224000V - 50 D Figure 4-9.

Clearance for the eMB-40M, Units in mm Key Meaning A 100 mm or more in front of Heat Sink for Wall Mounted B Wall C 200 mm or more aboveHeat Sink forFloor Mounted D Floor NOTE: These dimensions assume the eMB-40M has exposure to outside air, rather than being in a sealed container. Any sealed container would need to provide sufficient cooling for the eMB-40M’s internal fan to be effective. Surface Air Gap Back 0 mm Sides 50 mm (2 inches) Front, when wall-mounted 100 mm (4 inches) Front, when flat-mounted 200 mm (8 inches) XSYSTEM STA EXPIO ENET ENET TUS BRAKE 50 Surface Air Gap ack 0 mm des 50 mm (2 inches) ont, when wall-mounted 100 mm (4 inches) ont, when flat-mounted 200 mm (8 inches)