omron — List of Cables and Parts

5.1 System Cables(without SmartController EX option) 46 Cobra 450, 500, and 650 User's Guide 19148-000 Rev. E t of Cables and Parts In the Accessory box, locate the eAIB XSYSTEM cable. Connect the cables and peripherals as shown in the preceding figure. Parts and steps are covered in the following two tables. Part Cable and Parts List Part # Standard Option User- Supplied A eAIB XSYSTEM Cable Assembly 13323-000 X A1 XUSR Connector X A2 XFP Connector X A3 XMCP Connector X B User E-Stop, Safety Gate n/a X XUSR for User E-Stop/Safety Gate and Muted Safety Gate. The Jumper Plug is required if neither of these is used.

C XUSR Jumper Plug 04736-000 X D Front Panel 90356- 10358 X E Front Panel Cable 10356- 10500 X F Front Panel Jumper Plug 10053-000 X Either Front Panel or FP plug must be used. G XMCP Jumper Plug 10052-000 X H T20 Bypass Plug 10048-000 X J T20 Adapter Cable 10051-003 X K T20 Pendant (option) 10054-010 X Either T20 Pendant,T20 Bypass Plug, or XMCP Jumper Plug must be used.

L VAC Power Cable 04118-000 X X L1 200 - 240 VAC, 10 A, Single-phase X M 24 VDC Power Cable 04120-000 X X N 24 VDC, 6 A Power Supply 04536-000 X X O Ground - eMB-40M, SmartVision MX, Robot Interface X P Ethernet Cable - PC -> PLC (Only while programming) n/a X Q Ethernet Cable to eMB-40M n/a X R Ethernet Cable to SmartVision MX n/a X S Ethernet switch, cable for SmartVi- sion MX. n/a X