omron —  Properties

⚫ Properties 20 Property Description Input Mode Input Range/ Default Data Type General Name Name Object name. Must not be overlapped in a screen. Direct input Character string (1 to 127) SignatureViewer0 Type Object type. Not changeable. - - SafetyCPU IAG 7inch.

_ _ SignatureViewer Version IAG version - - 1.3.0.0 Publisher Publisher IAG publisher - - Omron Promotion Sample Appearance Background Color Background Color Background color of a page Item selection Direct input Color pallet Character string Transparent1 Layout ▼Position (Left , Top) ▼Position (Left , Top) Position setting of object on a page.2 Direct input Spin button Numeric Numeric - Left Horizontal position (X-axis) of the top-left corner of an object on a page. Direct input Spin button Numeric Numeric - Top Vertical position (Y-axis) of the to-left corner of an object on a page. Direct input Spin button Numeric Numeric - ▼Size (Width, Height) Object size setting.

Direct input Spin button Numeric Numeric (760,390) Width Width of object Direct input Spin button Numeric Numeric 760 Height Height of object。 Direct input Spin button Numeric Numeric 390 Input FinishReadConfigration FinishReadConfigration Completion flag for configuration reading Variable specification Boolean (Blank) RegisteredUserName Username who is permitted to register the safety signature Variable specification String (Blank) Input/Output ControllerName ControllerName Controller name of connected unit Variable specification String (15) (Blank) CheckController Check flag for unit connected with the safety CPU unit.

Variable specification Boolean (15) (Blank) SafetyCPUPosition Place to where the safety CPU unit is connected. Variable specification String (15) (Blank) SelectUnitNo The number of selected unit. Variable specification Short (Blank) SignatureSetting Flag for the registered signature which stored in NA. Variable specification 3 Boolean (15) (Blank) NA Signature _ Signature information which stored in NA. Variable specification 3 String (15) (Blank) NA LastModffied UTC _ _ UTC of the registered signature which stored in NA. Variable specification 3 String (15) (Blank) NA LastModffied _ Registration time of the registered signature which stored in NA.

Variable specification 3 String (15) (Blank) SignatureCompError Flag that shows safety signatures mismatching Variable specification 3 Boolean (15) (Blank) SignatureCompError RestoreFil Display of comparison with a safety signature of a restored file. Variable specification 3 Short (Blank) _ e CompRestoreFile CompRestoreFile Flag to compare restored files Variable specification 3 Boolean (Blank)