omron — Only the user whose name has been input to the variable RegisteredUserName can register the safety signature. The setting procedures for security and user on NA are as the following.

5-2-3 Password Setting for Safety Program Administrator When an administrator of the safety program manages the safety signature after equipment operation, an equipment designer must register an authority and a username first. Then, the safety program administrator will take over them. The administrator must change the password that the designer had registered at first to the new one. This section shows how to do it. 1. The equipment designer set the authority, login username, and temporary password as the safety program administrator designates. See “Security Setting for NA” for detailed 2. The designer tells the temporary password to the administrator when handing procedure.

the equipment over. The administrator changes the password in NA’s System Menu. Refer to “ How to Change the Login Password to NA” for details. ⚫ Security Setting for NA When you register a safety signature, password authentication is required. You must configure the security setting of NA before using this IAG. Only the user whose name has been input to the variable RegisteredUserName can register the safety signature. The setting procedures for security and user on NA are as the following. 25 1. Double-click [Configurations and Setup] – [Security Settings] in Multiview Explorer. 2. Click the [+] button enclosed in a red square, in [Roles and Access Levels]. 3.

Enter an authority title and click to check the access level boxes.