Environmental Immunity Heat-resistant Dimensions Installation Information 62 to 66 Page Reflective Fiber Units 51-A E32-D51R 2M (Free Cutting) E32-L86 2M (No Cutting) 51-F Sensing surface Two, 1 dia. M6Ч0.75 (SUS303) Opposite side 10, thickness 2.4 (Nickel-plated brass) Washer (Nickel-plated iron) Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on one side 33.5 30(B) A 2,000 4 dia. Two, 2.2 dia. 5.5 11 19±0.5 7 13( * ) 2.2 dia. 8.9 18 5.2 3.5 17.5 2,000 Two, 4 dia. Sensing head (SUS) 27 Flexible tube: (Stainless steel) Two, 2.8 dia. 4 dia. Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively.
The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. Model Index Technical Guide and Precautions 51-B E32-D51 2M (Free Cutting) 51-G E32-A09H2 2M (No Cutting) M6Ч0.75 (Nickel-plated brass) Sensing surface Lenses 5.8 dia. 9 (SUS303) Two, 2.8 dia. flexible tubes (SUS304) Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on both sides Sensing surface Two, 1.5 dia. Opposite side 10, thickness 2.4 (Nickel-plated brass) Washer (Nickel-plated iron) Two, 2.2 dia. 4.9 24 4 dia. 2.2 dia. 8.9 * 3.1 13 3 17 2,000 7 12 30 A 2,000 5 28 (B) Note:
The maximum allowable temperatures for sections A and B are 300°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. 51-C 51-H E32-D81R-S 2M (No Cutting) E32-D611-S 2M (No Cutting) Opposite side 10, thickness 2.4 (SUS303) Washer (SUS) M4Ч0.7 M6Ч0.75 (SUS303) Opposite side 7, thickness 2.4 (SUS) Washer (SUS) M4Ч0.7 (SUS304) Sensing surface 1.2 dia. Protective tube 2.2 dia. Fluororesin tube Sensing surface 1 dia. SUS flexible tube 2.9 dia. 2.2 dia. BGS 3 2 4.5 8.5 2.4 4 dia. 20 28 8.5 4.5 20 5 (70) A 2,000 25 (B) * 5 Note:
The maximum allowable temperatures for sections A and B are 350°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. A 25 (B) 2,000 * 5 Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. 51-I E32-A08H2 2M (No Cutting) E32-D61-S 2M (No Cutting) 51-D M6Ч0.75 (SUS303) 5 Two, 3.4 dia. mounting holes with two, 6.3 dia. countersinks on one side 1.5 4 dia. 8.6 (5) Sleeve (Aluminum) Sensing surface 1.4 dia.
SUS flexible tube 3.5 dia. M4Ч 0.7 Opposite side 10, thickness 2.4 (SUS303) Washer (SUS) 2.2 dia. 5 dia. *2 Heat- resistant 18 4 dia. 2.2 dia. 4.5 8.5 Area Detection Sensing surface 4 10.7 (SUS303) Flexible tube: Two, 2.9 dia (Stainless steel) * 3 2 A 25 (B) 20 5 *3 2,000 * 1 5 26 6.5 A 2,000 30 (B) *2. The diameter is 6 dia. if the fiber length exceeds 10 m. *3. The length is 10 if the fiber length exceeds 10 m. Note: The maximum allowable temperatures for sections A and B are 350°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by * 1) must be maintained within the Amplifier Unit's operating temperature range. Liquid-level Applications Note:
The maximum allowable temperatures for sections A and B are 300°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. 6.5±0.1 Two, M3 Vacuum Mounting holes 51-J E32-D73-S 2M (No Cutting) FPD, Semi, Solar Opposite side 7, thickness 2.4 (SUS304) Washer (SUS) M4Ч0.7 (SUS303) Installation Information Two, 3.4 dia. mounting holes with two, 6.3 dia. countersinks on one side E32-L64 2M (No Cutting) 51-E A Sensing surface 1 dia. Stainless-steel tube 1.25 dia. SUS flexible tube 2.8 dia. 2.5 dia. 1.65 dia. 4 dia. 2.2 dia.
Fiber Amplifiers, Communications Unit, and Accessories 5 25 18 2,000 30(B) 13( * ) 5 4.5 8.5 4 dia. 2.2 dia. 5 60 20 10 2,000 5 A B 25 (C) * 8.9 18 Note: The maximum allowable temperatures for sections A, B, and C are 400°C, 300°C, and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. Two, 4 dia. 11 10.7 6.5 Sleeve (Aluminum) Sensing head (SUS) Flexible tube: (Stainless steel) Two, 2.9 dia. Note: The maximum allowable temperatures for sections A and B are 300°C and 110°C, respectively.
The section inserted into the Amplifier Unit (indicated by * ) must be maintained within the Amplifier Unit's operating temperature range. 51 51 Fiber Sensor Features Selection its Guide Fiber Un Threaded Standard Installation Hex-shaped Cylindrical Space Flat Sleeved Saving Small Spot High Power Narrow view reflective Limited- reflective Transparent Obj Chemical- resistant, Oil-resistant Bending