Downloaded from https://www.everyspec.com MIL-STD-2031(SII) APPENDIX A STANIIAR1) OPERATING PROCEDURE FOR C)XYG EN- ‘l.i:hll)l’;liA’I’l Jltl; lNIIEX I’I?OL’lLE 10. SCOI’E 10.1 Scope. This method describes a procedure to measure the minimum oxygen eon- centratirm at temperatures from ambient, 25 degrees Celsius (“C) (75 degrees Fahrenheit (“F)), to an elevated temperature, 300 (570 ‘F), in a tlowing mixture of oxygen and nitrogen that will just support flaming eombusticm. This procedure modifies ASTM D 2863 to measure the oxygen index at elevated temperatures. This appendix is a mandatory part of the standard. The information contained herein is intended for compliance. 20.
APPLICABLE DOCUMENTS 20.1 Non-Government publications. The [ollowing document(s) form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DOD adopted are those listed in the issue of the DODISS cited in the solicitation. Unless otherwise specified, lhc issues of documen[s not lis{ed in the DODISS are the issues of the documents cited in the solicitation (see 6.2).
AMERICAN SOCIETY FOR TESTING AND MATERIALS (A!Hlvi) D 2863 Standard Test Method For Measuring The Minimum Oxygen bncentration to Support Candle - Like Combustion of Plastics (Ckxygen Index) (Application for copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) (Non-Government standards and other publicat irms are normally available from the organizations that prepare or distribute the documents. These documents also may be available in or through libraries or other informational services.) 30. EQUIPMENT 30.1 Equ@nenL The Stanton-Redcroft ~A/HITA apparatus or its equivalent shall be used for this test.
The procedure deseribed is for the Stanton-Redcroft device