Hantek — TRIGger:UART:PARIty

TRIGger:UART:DATA For example, :TRIGger:UART:DATA 10 /*Set the data value to 10*/ :TRIGger:UART:DATA? /*The query returns 10*/ TRIGger:UART:WIDTh For example, :TRIGger:UART:WIDTh 5 /*Set the data bit width to 5*/ :TRIGger:UART:WIDTh? /*The query returns 5*/ TRIGger:UART:STOP For example, :TRIGger:UART:STOP 2 /*Set stop bit 2*/ :TRIGger:UART:STOP? /*The query returns 2*/ TRIGger:UART:PARIty 90 / 136 Command format :TRIGger:UART:DATA :TRIGger:UART:DATA? Function description Set or query the data value when the UART trigger condition is data. Parameter Name Type Range Default Discrete 0 to 2𝑛-1 00 Description n is the current data width, and the value range is 5, 6, 7, or 8.

Return format The query returns an integer. Command format :TRIGger:UART:WIDTh :TRIGger:UART:WIDTh? Function description Sets or queries the data bit width when the UART trigger condition is data. Parameter Name Type Range Default Discrete {5|6|7|8} 8 Return format The query returns 5, 6, 7, or 8. Command format :TRIGger:UART:STOP :TRIGger:UART:STOP? Function description Set or query the stop bit when the UART trigger condition is an error frame. Parameter Name Type Range Default Discrete {1|2} 1 Return format The query returns 1 or 2. Command format :TRIGger:UART:PARity :TRIGger:UART:PARity?

Function description Set or query the verification mode when the UART trigger condition is an error frame or a verification error. Parameter Name Type Range Default Discrete {EVEN|ODD|NONE} NONE Description When the trigger condition is a verification error, the verification method cannot be set to NONE. At this time, the verification method defaults to odd