Basic Operation Holdoff: To use Trigger Holdoff, push the HORI button and set the Holdoff Time option. The Trigger Holdoff function can be used to generate a stable display of complex waveforms (such as pulse trains). Holdoff is the time between when the oscilloscope detects one trigger and when it is ready to detect another. During the holdoff time, the oscilloscope will not trigger. For a pulse train, the holdoff time can be adjusted to let the oscilloscope trigger only on the first pulse in the train.
Acquisition Interval Acquisition Interval Trigger Level Indicates Trigger Points Holdoff Holdoff 5.5 Menu and Option Buttons As shown below, these four buttons at the front panel are used mainly to recall relative setup menus. SAVE/RECALL: Displays the Save/Recall menu for setups and waveforms. MEASURE: Displays the Measure menu. UTIILITY: Displays the Utility menu. CURSOR: Displays the Cursor menu. 5.5.1 SAVE/RECALL Press the SAVE/RECALL button to save or recall oscilloscope setups or waveforms.
DSO1000B(V) Series HandHeld Oscilloscope User Manual 30 Mode Auto Normal Overtime Coupling AC DC Noise Reject HF Reject LF Reject Selects the components of the trigger signal applied to the trigger circuitry. 50% Options Settings Comments Wave Enter the Save Wave menu. Setup Enter the S/R Setup menu. CSV Enter the CSV menu.