Hantek — 5.5.2 MEASURE

Basic Operation 5.5.2 MEASURE Push the MEAS button to perform auto measurements. There are 32 types of measurements and up to 4 types can be displayed on the screen. User can turn directions keys to select measurement item, or push “ Modify -> Type ” to select the measurement type. Press “ Modify ” button to select the measure source (CH1 or CH2) and measure type. Then press “ OK ”button to change successfully. DSO1000B(V) Series HandHeld Oscilloscope User Manual 31 Default Recall default setup. Save Wave Save the screen picture. Options Settings Comments Wave Source CH1 CH2 Select a waveform display to store. Media USB Flash SD Select media.

Location 0-1000 Save Save the source waveform to the selected reference location. Recall Display the reference waveform on the screen. Delete Delete waveform. Options Settings Comments Setup Source Local USB disk Store the current setups to the USB disk or the memory of the oscilloscope. Location 0 to 9 Specify the memory location in which to store the current waveform settings or from which to recall the waveform settings. Save Complete the saving operation. Recall Recall the oscilloscope settings stored in the location selected in the Setup field. Push the Default Setup button to initialize the oscilloscope to a known setup.