DeviceNet Network Scanner DVPDNET-SL 5) Application example (II) 1> The connection Note: IFD9502, a Delta DeviceNet slave module can connect the temperature controller to DeviceNet 2> Compulsory settings and explanations on devices network. „ Compulsory settings in DVPDNET-SL „ Compulsory settings in DNA02 „ Compulsory settings in VFD-B DVP-PLC Operation Manual 19 Target M1 = On, set 0x99>>Instance 1>>Attribute 2 of IFD9502 to “0004Hex”. Parameter Set value Explanation Node address 00 Set the node address of DVPDNET-SL to “00”. Baud rate 500kbps Set the communication speed of DVPDNET-SL and bus to “500kbps”.
Parameter Set value Explanation Node address 02 Set the node address of DNA02 to “02”. Baud rate 500kbps Set the communication speed of DNA02 and bus to “500kbps”. Parameter Set value Explanation 02-00 04 The main frequency is operated on RS-485 interface. 02-01 03 The operation commands are operated on the communication interface. Operation by keys is valid. 09-00 01 Communication address of VFD-B: 01 09-01 03 Baud rate: 38,400 09-04 03 Modbus RTU mode. Data format