Software 4.2.3 Set operand functions When you are planning your project, please take into ac- count that some of the operands listed above have set func- tions: 4.2.3.1 Operands reserved for monitor functions These operands must not be used for any other purposes. Failure to obey may render the controller functions unsafe. 4.2.3.2 Operands reserved for KUBES modules Eco Control 667E has no KUBES module parameters. Indi- vidual KUBES modules use defined operands that you should reserve in case you wish to use these operands. If you wish to embed one or several of the above KUBES modules in your project, you must make sure that the rele- vant operands are reserved for this purpse only.
46 Operand Function SLG14.00 Internal use SLG14.01 Undervoltage monitoring (n * 10 ms) SLG14.02 Reads inputs in case of undervoltage SLG14.03 Internal use SLG14.04 Internal use SLG14.05 Generates the intermediate code SLG14.06 Transmitting projects: retains remanent data Operand Used by KUBES module BM00.00...03 WR OFFS, RD OFFS _ _ BM01.00 FBM00.00...01 FBM01.00...09 V24667IS, V24667IE, V24667IN