omron — Option Cards

Option Cards 1 2 : : PG speed control card is required for PG control. Under development. Notes : DeviceNet is a registered trademark of the Open DeviceNet Vendor Association(ODVA). LONWORKS is a registered trademark of Echelon Corp. 20 Type Name Code Number Function Document Number connector) to (connect Built-in Speed (Frequency) Reference Option Cards Analog Reference Card AI-14U 73600-C001X Enables high-precision, high-resolution setting of analog speed references. Input signal level : 0 to +10 VDC (20 kΩ), 1 channel 4 to 20 mA DC (250 Ω), 1 channel Input resolution :

14-bit (1/16384) TOE-C736-30.13 Analog Reference Card AI-14B 73600-C002X Enables high-precision, high-resolution setting of analog speed references. Input signal level : 0 to +10 VDC (20 kΩ) 4 to 20 mA (500 Ω), 3 channels Input resolution : 13-bit + sign (1/8192) TOBP C730600 15 Digital Reference Card DI-08 73600-C003X Enables 8-bit digital setting of speed references. Input signal : 8-bit binary 2-digit BCD + sign signal + set signal Input voltage : +24 V (isolated) Input current : 8 mA TOE-C736-30.15 Digital Reference Card DI-16H2 73600-C016X Enables 16-bit digital setting of speed references. Input signal : 16-bit binary 4-digit BCD + sign signal + set signal Input voltage :

+24 V (isolated) Input current : 8 mA With 16-bit/12-bit switch. TOE-C736-40.7 Monitoring Option Cards Analog Monitor Card AO-08 73600-D001X Converts analog signals to monitor the MxC’s output status (output frequency, output current, etc.) to absolute values and outputs them. Output resolution : 8-bit (1/256) Output voltage : 0 to +10 V (not insulated) Output channels : 2 channels TOE-C736-30.21 Analog Monitor Card AO-12 73600-D002X Output analog signals to monitor the MxC’s output status (output frequency, output current, etc.). Output resolution : 11 bits (1/2048) + sign Output voltage : −10 to +10 V (not insulated) Output channels :

2 channels TOE-C736-30.22 Digital Output Card DO-08 73600-D004X Outputs isolated digital signals to monitor the MxC’s operating status (alarm signals, zero-speed detection, etc.) Output form: Photocoupler outputs, 6 channels (48 V, 50 mA max.) Relay contact outputs, 2 channels (250 VAC: 1 A max., 30 VDC: 1 A max.) TOE-C736-30.24 2C-Relay Output Card DO-02C 73600-D007X Provides two multi-function outputs (DPDT relay contacts) in addition to those provided by the MxC. TOE-C736-40.8 1 PG Speed Control Cards PG-B2 73600-A013X Used for Flux Vector Control. A-, B-phase input (complimentary input) Maximum input frequency: 32767 Hz Pulse monitor output: Open-collector (PG power supply output:

+12 V, 200 mA max.) TOBP C730600 09 PG-X2 73600-A015X A-, B-, Z-phase pulse (differential pulse) input Maximum input frequency: 300 kHz Input: Conforms to RS-422 Pulse monitor output: RS-422 (PG power supply output: + 5 V or +12 V, 200 mA max.) TOBP C730600 10 Communications Option Cards MECHATROLINK Interface Card SI-T 2 Used to communicate with the MxC from a host controller using MECHATROLINK to start/stop MxC operation, read/set parameters, and read/set monitor parameters (output frequencies, output currents, etc.).

− DeviceNet Interface Card SI-N1 2 Used to communicate with the MxC from a host controller using DeviceNet to start/stop MxC operation, read/set parameters, and read/set monitor parameters (output frequencies, output currents, etc.). − CC-Link Interface Card SI-C 73600-C032X Used to communicate with the MxC from a host controller using CC- Link to start/stop MxC operation, read/set parameters, and read/set monitor parameters (output frequencies, output currents, etc.).

TOBZ-C736-70.6 Profibus-DP Interface Card SI-P1 2 Used to communicate with the MxC from a host controller using Profibus-DP to start/stop MxC operation, read/set parameters, and read/set monitor parameters (output frequencies, output currents, etc.). − LONWORKS Interface Card SI-J 2 Used to communicate with the MxC from a host controller using LONWORKS to control HVAC, start/stop MxC operation, read/set parameters, and read/set monitor parameters (output frequencies, output currents, etc.).

− CANopen Interface Card SI-S1 2 Used to communicate with the MxC from a host controller using CANopen to start/stop MxC operation, read/set parameters, and read/set monitor parameters (output frequencies, output currents, etc.). −