Hantek — Руководство по эксплуатации DC Regulated Power Supply Hantek HDP10000 (EN)

Quick start EN Press the to enable the OCP function. The indicator light will be on. Press again to disable the OCP function, the indicator will be off. Long press to enter the setting mode, use the current value adjustment knob to change the OCP set value. When the actual output current value is higher than the OCP set value, the protection function will be triggered and the screen will display . The output is forcibly turned off, but the ON/OFF indicator light is not turned OFF. Press to clear the error and turn off the indicator light. 11. Voltage value adjustment knob It is the same as the current value adjustment knob. 12. Press the to enable OVP function.

The indicator light will be on. Press again to disable OVP function. The indicator light will be off. Long press to enter the setting mode and use the voltage adjustment knob to change the OVP set value. When the actual output voltage value is higher than the OVP set value, the protection function will be triggered and will be displayed on the screen. The output is forcibly turned off, but the ON/OFF indicator light is not turned off. Press to clear the errors and turn off the indicator light. 13. CC constant current output state Under constant current working state, the status indicator will be on. 14. Button lock Press . The indicator light will be on.