HP — DC controller connections

Location of connectors DC controller connections Figure 1-2 DC controller connections J2400 J2103 J2104 J2102 J2704 J2703 J2311 J2308 J2401 J2303 J2701 J2301 J2302 J2310 FT2 J2100 J2700 J2306 FT1 J2105 J2307 J2304 J2200 J2702 J2201 ENWW Service approach 7 Item Description Item Description Item Description J2100 Not used J2302 MPT media out sensor (PS205) J2400 Fuser output sensor (PS2) TH1/TH2 J2102 Fuser motor (M8002) J2303 Face-up sensor (PS1) Output bin full sensor (PS4) J2401 J2103 Main motor (M8003) J2304 Environmental sensor (TH3) J2700 LVPS