Delta — Chapter 4 Communication Setting

Chapter 4 Communication Setting Laser Displacement Operating Manual 4-4 DI/DO NO/NC 0x01: DI is OFF、DO is ON 0x10: DI is ON、DO is OFF 0x11: DI/DO is ON Low byte: 0x00:DI/DO is NC 0x01: DI is NC、DO is NO 0x10: DI is NO、DO is NC 0x11: DI/DO is NO AA51H (R/W) (03H,06H) Output delay mode setting 0x00: Normal output、0x01: Off-delay; 0x02: On-delay; 0x03: One-shot AAB5H (R/W) (03H,06H) Output delay time setting 0~1000ms AB19H~AB1AH (R/W) (03H,10H) Relative lower limit setting -120000um~120000um  relative position (numbers) AB7DH~ AB7EH (R/W) (03H,10H) Relative upper limit setting -120000um~120000um  relative position (numbers) AFC9H (R/W) (03H,06H) Set the zero value 0x00:

Reset the zero value 0x01: set to zero 84D1H~84D2H (R/W) (03H,10H) Read the zero value Read the set zero value B3B1H (R/W) (03H,06H) Communication setting 0x00: 8,O,1/2 0x01: 8,N,1/2 0x03: 8,E,1/2 ABE1H (R/W) (03H,06H) Set external input function 0x00: None 0x01:Set-zero 0x02: Trigger 0x03: Laser-off A9EDH (R/W) (03H,06H) Set shutter level High byte: 0x00Manual 0x01Auto Low byte: 0x00~0x0F 15 levels can be adjusted, if it is in the automatic mode, it cannot be set.