lexus — Decoding Mode 06 data

In--46 -- Introduction General Information TID $04: HO2S heater TID $05: EGR (a) EGR temperature/idle misfire monitor and stepper motor type (b) EGR temperature/EGR valve lift monitor (c) MAP/idle misfire monitor TID $06: A/F sensor TID $07: A/F sensor heater TID $08:

Thermostat TLT CID Unit Conversion Description of Test Value Description of Test Limit 1 $01 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 1) Malfunction criterion 1 $02 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction criterion 1 $04 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 3) Malfunction criterion 1 $10 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 1) Malfunction criterion 1 $20 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 2) Malfunction criterion 1 $40 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 3) Malfunction criterion TLT CID Unit Conversion Description of Test Value Description of Test Limit 1 $01 Multiply by 0.625 and subtract 40 [˚C] Test value for EGR insufficient flow:

Determined by EGR temperature 0˚C 1 $02 Multiply by 0.625 and subtract 40 [˚C] Test value for EGR excessive flow: Determined by EGR temperature 0˚C TLT CID Unit Conversion Description of Test Value Description of Test Limit 1 $01 Multiply by 0.625 and subtract 40 [˚C] Test value for EGR insufficient flow: Determined by EGR temperature 0˚C 1 $02 Multiply by 0.625 and subtract 4 [mm] Test value for EGR excessive flow: Determined by EGR valve lift 0 mm TLT CID Unit Conversion Description of Test Value Description of Test Limit 1 $01 Multiply by 2.44 and subtract 156.16 [mmHg] Test value for EGR valve stuck closed:

Determined by intake manifold pressure 0 mmHg TLT CID Unit Conversion Description of Test Value Description of Test Limit 0 $01 Multiply by 0.000244 [No dimension] Parameter that identifies A/F sensor response rate (Bank 1) Malfunction criterion 0 $11 Multiply by 0.000244 [No dimension] Parameter that identifies A/F sensor response rate (Bank 2) Malfunction criterion TLT CID Unit Conversion Description of Test Value Description of Test Limit 1 $01 Multiply by 0.000076 or 0.00017 [A] Maximum heater current (Bank 1) 0.25 A 1 $10 Multiply by 0.000076 or 0.00017 [A] Maximum heater current (Bank 2) 0.25 A TLT CID Unit Conversion Description of Test Value Description of Test Limit 1 $01 Multiply by 0.625 and subtract 40 [˚C] ECT sensor output when estimated ECT reaches malfunction criterion Malfunction criterion