MC-909 1. Turn on the power of the MC-909. 2. Hold down the [SHIFT] button and press the [F5] button. 5. Press the [F6] button, and the [Service Utility] screen will appear. The LCD display will show the following. The System screen will appear, and the LCD display will show as follows. fig.test1_70 fig.serviceutil_70 6. Press the [F5] button and the [Voltage Update Mode] screen will appear. The LCD display will show the following. 3. Press the [F6] button. The System Info screen will appear, and the LCD display will show as follows. fig.voltage_70 fig.test2_70 7. Specify the destination region. 4.
Hold down the [SHIFT] button and press the part buttons (see figure below) in the order of [1] -> [7] -> [8] -> [9]. If you press the [F1] button, the LCD display will show “100V (JAPAN) [OK],” and the 100V destination region setting will be made. part.eps If you press the [F2] button, the LCD display will show “117V (U, U/CS) [OK],” and the 117V destination region setting will be made. If you press the [F3] button, the LCD display will show “230V/240V (EU, E, A) [OK],” and the 230V/240V destination region setting will be made. 8.
When you have made the setting, turn off the power of the MC-909, turn it back on again, and verify that the destination region has been changed to the setting you made. Verify that the names and numbers of the preset patterns immediately after power-on are as follows. The MC-909 Menu screen will appear, and the LCD display will show as follows. (You can use the [INC] button and [DEC] button to change the pattern number.) fig.test3_70 “100V”: P001 R&B 1, P002 Euro Trance 1, P003 Garage 1, P004 Minimal 1, P005 G-Funk 1 “117V”: P001 R&B 1, P002 Euro Trance 1, P003 Garage 1, P004 Minimal 1, P005 G-Funk 1 “230V,240V”:
P001 R&B 1, P002 Euro Trance 1, P003 Garage 1, P004 Minimal 1, P005 G-Funk 1 31