omron — Руководство по эксплуатации Omron STC-HD213 Series — Камера с цветным (EN)

No. 20S125-00 7.3 Button Description Read out All of DPS register and uCOM register settings on camera. Please execute this button when turning on camera every time. Read All DSP -> EEPROM Save the DSP register settings (that settings are on DSP tab) into EEPROM. uCOM -> EEPROM Save the uCOM register settings (that settings are on uCOM tab) into EEPROM. EEPROM -> DSP Read the DSP register settings on EEPROM. EEPROM -> uCOM Read the uCOM register settings on EEPROM. 7.4 The Differences of uCOM register and DSP register Mainly video control functions are in DSP register area. The communication settings and other functions as button setting are in uCOM register.

DSP has the eight User presets and user can configure each DSP Preset for each application. STC-HD213DVN-B / STC-HD213SDIN-B Product Specifications and User’s Guide 30/89