Delta — Load Cell Module DVP02LC-SL — Operation Manual by Delta Electronics (EN)

Load Cell Module DVP02LC-SL 5.2 Explanations on Control Registers CR#0: Model name Explanations: The model code of DVP02LC-SL is H’4206. CR#1: Firmware version Explanations: The high byte is the ones digit, and the low byte is the tenths and hundredths digits, e.g. V1.01 = H’0101. CR#2: Eigenvalue Explanations: Since load cells of different brands own different specifications, please set up eigenvalues for DVP02LC-SL following the instructions and specification of the load cell you use. DVP-PLC Operation Manual 11 CR# Address Attribute Content b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 #50 H’1032 X R Status code b0 (H’0001): CH1 zero point weight (empty) b1 (H’0002):

CH2 zero point weight (empty) b2 (H’0004): CH1 exceeds max. weight (overload) b3 (H’0008): CH2 exceeds max. weight (overload) b4 (H’0010): CH1 measured value is stable. b5 (H’0020): CH2 measured value is stable. b6 to b15: Reserved #51 H’1033 X R Error code Storing all error statuses. See the “Error Code” table. #52 H’1034 O R/W RS-232 node address For CR#52 and CR#54, the default value is K1 and the range is K1 to K255. For CR#53 and CR#55, the default value is H’0000 and the range is “ASCII, 9600, 7, E, 1”. See the “Communication Format” table. #53 H’1035 O R/W RS-232 communication format #54 H’1036 O R/W RS-485 node address #55 H’1037 O R/W RS-485 communication format Symbols:

O means latched; X means non-latched; R means able to read data; W means able to write data. Value to be set in CR#2 Specification Eigenvalue you need Note 0 1 mV/V H’0000 1 2 mV/V H’0001 Default 2 4 mV/V H’0002 4 6 mV/V H’0003 Eigenvalue > 6 mV/V Not supported