Delta — Load Cell Module DVP02LC-SL — Operation Manual by Delta Electronics (EN)

Load Cell Module DVP02LC-SL 100ms (10 Ч 10ms) and the range returns to be within 1,000, bit4 and bit5 of CR#50 will be set to 1 again. We recommend you check if the measured value is stable enough before controlling it. △ : change of average weight t: measuring time set up by user k: range for standstill check set up by user m: times of standstill checks set up by user t k m △ △ △ Average weight >k △ >k >k >k △ >k △ >k >k △ >k >k △ >k >k △ >k △ >k △ >k m t Time bit4 & bit5 of CR#50 bit „ Relevant control registers y CR#16,17: Times of standstill check y CR#18,19:

Range for standstill check 5.3.3 Determining Zero Point You can use the zero point determination function to know if the object has been removed from the load cell. If the bit4 and bit5 of CR#50 are 1, and the bit0 and bit1 are 1 as well, the object has been removed from the load cell already, and you will be able to perform the next step of the control. Average weight Range for zero point weight Time Zero point weight „ Relevant control registers y CR#37, 38, 39, 40: Upper/Lower limits for zero point check 5.3.4 Filtering The average value is a steady value obtained from the sum of the read values.

However, due to unavoidable external factors, the read values may be an acute pulse, resulting in fierce changes in the DVP-PLC Operation Manual 18 DVP ct to ured CH1 Load cell CH2 02LC-SL