• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible: 1 2 RS-232 Hardware Configuration or USB to activate the appropriate display. Configure settings as required by the application, and click Connect . Important: The reader is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the field of view while attempting to connect. Step 2 — Connect the System 5 3 4 Connecting by USB • Connect the reader ( 1 ) to the host computer. The reader is powered by the USB connection. 6 Connecting by RS-232 • Connect the reader ( 1 ) to the IB-131/IC-332 interface ( 2 ) and ( 3 ).

• Connect the communication cable ( 6 ) to the host, and to the host port on the IB-131 ( 3 ). • Connect the object detector ( 5 ) to the IB-131 ( 3 ). • Connect the power supply ( 4 ) to the IB-131 ( 3 ). • Apply power to the reader. Connect 1 USB Hardware Configuration 1 RS-232 Hardware Required 1. Click the button showing the reader used in your application. 2. Click OK . Note: You can also simply double-click the button showing your reader to make your selection. 3. Click Yes when this dialog appears: Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables. USB Hardware Required 1 2 Note:

If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. 3 5 4 6 Step 1 — Check Hardware Important: USB models support USB 1.1 Keyboard Mode only. Virtual COM serial emulation is not supported. 4 Power Supply 97-000012-02 (90-264 VAC, 24VDC, USA/Euro plug) Step 4 — Select Model When you start ESP , this menu will appear:

Item Description Part Number 1 MS-2 CCD Reader FIS-0002-000XG Item Description Part Number 1 MS-2 CCD Reader FIS-0002-000XG 2 IC-332 Adapter FIS-0001-0035G 3 IB-131 Interface Box 99-000018-01 5 Object Detector 99-000017-01 6 Communication Cable 61-300026-03 RS-232 Hardware USB Hardware P/N 83-200002 -04 Rev A ESP Software can be found on the Microscan Tools Drive that is packaged with the MS-2. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program. Note: ESP can also be installed from the Download Center at Refer to the MS-2 CCD Reader User Manual for detailed information about using ESP to configure the MS-2.

• 800 x 600 256 color display (1024 x 768 32-bit color recommended) Quick Start Guide MS-2 CCD Reader Minimum System Requirements • 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) Step 3 — Install ESP • Internet Explorer 6.0 or higher www.microscan.com . • 128 MB RAM or greater • 160 MB free disk space Item Description Part Number 1 MS-2 CCD Reader FIS-0002-000XG Item Description Part Number 1 MS-2 CCD Reader FIS-0002-000XG 2 IC-332 Adapter FIS-0001-0035G 3 IB-131 Interface Box 99-000018-01 4 Power Supply 97-000012-02 (90-264 VAC, 24VDC, USA/Euro plug) 5 Object Detector 99-000017-01 6 Communication Cable 61-300026-03

Стр. 1

• Send, No Save . Changes will be lost when power is re-applied to the imager. • Send and Save . This activates all changes in current memory and saves to the imager for power-on. 5. Right click on the open screen and select Save to Reader to implement the command in the imager. Step 8 — Save Changes in ESP To make changes to a configuration setting: 4. Left click on the open screen to complete your selection. 1. Left click on the + to expand the desired tree. 2. Double click on the desired parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting.

• Click the Autoconnect button to establish communications between ESP and the reader. • Click the Send/Recv button to send or receive commands. • Click the Parameters button to show the tree controls for Communication, Read Cycle, and Symbologies. • Click the Terminal button to display decoded symbol data and to send serial commands to the reader using text or macros. • Click the Utilities button to test Read Rate, request or clear Counters, enable or disable the reader or send output pulses in Device Control, determine the Differences from Default in the current settings, add or remove master symbol data in Master Database, and verify or update the reader’s Firmware.

The following modes are accessible by clicking the buttons at the top of the screen: To make setup changes to the reader, click the App Mode button. Step 7 — Configure the Reader • Set up a symbol at the distance you will be using in your application. Refer to the read range data for your MS-2 model (High or Low Density) in the MS-2 CCD Reader User Manual . Note: If you are using an Interleaved 2 of 5 symbol, verify that the number or characters being scanned matches the symbol length enabled for Interleaved 2/5 (default is 10 and 6). • Avoid bright light or infrared light from other sources, including other readers.

• Pitch the reader or symbol at a minimum of ±15° to avoid specular reflection (the return of direct, non-diffused light). • Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. Note: Code 39 is the default symbology enabled. If you are uncertain of your symbology, perform the following steps: 1. Enable all symbologies using ESP . 2. Enable Symbology Identifier at the bottom of ESP ’s Symbologies tree control. 3. Decode the symbol and compare the symbology identifier character to the list on page 5-20 of the MS-2 CCD Reader User Manual to determine your symbology. Step 6 — Position Reader Reader / Symbol Positioning Copyright © 2017 Microscan Systems, Inc. 4.

Disable all other symbologies.

Стр. 2