Details of programs and protocol macro data used in this document are shown below. 9.1. Overview This chapter describes the specifications and functions of the program and protocol macro data used to check the connection between the smart camera (hereafter, sometimes referred to as the partnering device) and the controller (Serial Communication Unit (hereinafter SCU unit)). This program and protocol macro data use the protocol macro function of the SCU unit to send and receive "Serial Trigger" commands to and from the Partnering device to determine Normal/Abnormal termination. The program's normal termination is the normal termination of the protocol macro's send / receive sequence.
Also, abnormal termination is considered as abnormal termination of the Send / Receive sequence of the protocol macro. In this section, if it is necessary to distinguish between decimal data and hexadecimal data, add "10 #" (optional) to the beginning of decimal data and "16 #" to the beginning of hexadecimal data. (For example, "1000" or "10#1000" for decimal data, "16#03E8" for hexadecimal data) To specify the data type, add " #" at the beginning. (For example, "WORD#16#03E8") Note This project file only confirms that communication is possible for this test configuration, product versions, and product lots used for evaluation.
Operation is not guaranteed under disturbances such as electrical noise or variations in the performance of the device itself. 49 9. Program