NTS/NTU series are MEAN WELL's new generation high-reliability off- grid DC-AC pure sine wave inver ters. The whole family has N T S - 2 5 0 P / 4 0 0 P, N T S - 3 0 0 / 4 5 0 / 7 5 0 / 1 2 0 0 / 1 7 0 0 / 2 2 0 0 / 3 2 0 0 , and NTU-1200/1700/2200/3200 series . The whole family of NTS/NTU are fully digital designed, with three major characteristics of miniaturization, high efficiency, and intelligence. The main features are, instantaneous peak load capacity which can reach up to 2 times of output wattage, as well as AC output voltage/frequency/power saving mode adjustment capability through the DIP switch of front panel (the idle standby consumption is 1.5W).
It s efficiency reaches up to 93%, and it can be operated within temperature range from -25~+70 . Built-in remote control, able to monitor the battery voltage and the load status of the inverter through IRC1/2/3. Not only intergrated multiple intelligent p r o t e c t i o n s , b u t a l s o p a s s e d s a f e t y r e g u l a t i o n s s u c h a s CB/DEKRA/E13/EAC/UL/RCM/FCC/CE/UKCA. Materials and components are strictly selected and 3-year warranty is provided. It is suitable for households, vehicles, yacht and remote areas without power grids.
Common application such as, lighting, air conditioning, refrigerators, hair dryers, microwave ovens , computers, televisions, hand-held power tools, motor equipment, mobile AC power... etc.
2026.03 Ver 12 61 61 62 63 64 6 Protections and Failure . 8.Environmental declaration information 6.2 Failure Correction 6 1 Protections . Correction 7 Warranty . 1 2 2 2 3 16 17 18 24 24 24 25 25 26 26 27 27 29 30 32 32 34 34 35 59 2 6 Mechanical specification . 3 2 . System Block Diagram 3 Installation procedures .3 5.1 Procedure of Setting Operating Mode,Output Voltage,Frequency,and / / 5.3 IRC1 IRC2 IRC3 Remote 5.4 RS-232 UART protocol / 2 3 Main specification . 2.4 Safety Overview 3.Installation & Wiring 3 .5 Battery selection 4. User Interface Panel 5 Explanation of settings . power Saving Mode 5.2 Function difference 5 5 UPS mode(only for . 1 Safety Guidelines . 2 1 Model number .
2 5 Derating curve . 3 Precautions .1 3 .4 Cable selection 3.6 GFCI socket 4 3 LED indicator . control unit NTU series) 2 Introduction . 2.2 Features 4.1 AC panel 4.2 DC panel Index
2.2 Features
2 DC Input voltage (12: 12Vdc, 24: 24Vdc, 48: 48Vdc) AC output voltage (1: 100~120Vac, 2:200~240Vac) DC Input Reverse polarity protection/ Low DC voltage protection/ AC Output Short circuit protection, over load protection, over Wide range of DC input voltage for lead acid or lithium battries. AC Socket (US EU CN AU UK UN GFCI) AC voltage, frequency, power saving mode selectable. LED indicator Status, DC input, load status, AC input. Rated power (250W~3200W) Full digital design with compact size and light weight.
Support IRC1/2/3 for 750~3200W models(optional) Series name (NTS, NTU) True sine wave output(THD Multiple intelligent protections UPS functions( only for NTU series) Peak power up to 1.7~ 2 times DC over voltage protection. temperature protection. Built-in Remote control 1 12 US NTS 300 2 Introduction . 2.1 Model number 3 year warranty 2.2 Features Risk of electrical shock and energy hazard. All failures should be examined by the qualified technician. Please do not remove the case of the inverter by yourself. Please do not install the inverter in places with high ambient temperature or Please only connect batteries with the same brand and model number in one battery bank.
Using batteries from different manufacturers or different capacity Never allow a spark or flame in the vicinity of the batteries because they may Make sure the air flow from the fan is not obstructed at both sides (front and Please do not turn on the inverter before start the engine if inverter connected Branch rated over current protection for the output circuit is to be provided AC Risque de choc йlectrique et danger d'йlectrocution. Toutes les pannes doivent кtre examinйes par un technicien qualifiй. Veuillez ne pas retirer vous-mкme le N'installez pas l'onduleur dans des endroits trиs humides ou а proximitй d'eau.
N'installez l'onduleur dans des endroits ощ la tempйrature ambiante est йlevйe Veuillez ne insйrer que des batteries de la mкme marque et du mкme modиle dans un seul banc de batteries. L'utilisation de batteries de fabricants diffйrents Ne laissez jamais une йtincelle ou une flamme а proximitй des batteries car elles Assurez-vous que le flux d'air du ventilateur n'est pas obstruй des deux cфtйs N'allumez pas l'onduleur avant de dйmarrer le moteur si l'onduleur est connectй Une protection contre les surintensitйs nominales de dйrivation pour le circuit Please do not install the inverter in places with high moisture or near water. (avant et arriиre) de l'onduleur.
(Veuillez laisser au moins 15 cm d'espace) peuvent enflammer des gaz explosifs lors du fonctionnement normal. back) of the inverter. (Please allow at least 15cm of space) de sortie AC doit кtre fournie au moment de l'installation. ou de capacitйs diffйrentes est strictement interdite! ignite explosive gases during normal operation. Please do not stack any object on the inverter. ou sous la lumiиre directe du soleil. N'empilez aucun objet sur l'onduleur. directement а la batterie du vйhicule. 1 1 Safety Guidelines . to vehicle's battery directly. at the time of installation. under direct sunlight. is strictly prohibited! bootier de l'onduleur. 1 1 12 US
2.3 Specification
2 NTS-400P-248 40 ~ 66Vdc 1Vdc ± 1Vdc ± 1Vdc ± 1Vdc ± 1Vdc ± 1Vdc ± ) 10A*2 Power ON-OFF remote control by front panel dry contact connector (by RELAY) Open : Normal work ; Short : Remote off FUNCTION Protection type : Shut down o/p voltage, re-power on to recover STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing o WORK TEMP.
-20 ~ +70 (Refer to “Derating curve”) WORKING HUMIDITY 20 ~ 90% RH non-condensing REMOTE CONTROL DRY CONTACT ENVIRON- MENT NTS-250P-112 NTS-250P-124 NTS-250P-148 NTS-250P-212 NTS-250P-224 100 / 110 / 115 / 120Vac selectable by DIP S.W VOLTAGE RANGE (Typ.) 10 ~ 16.5Vdc 10 ~ 16.5Vdc 20 ~ 33Vdc 20 ~ 33Vdc 40 ~ 66Vdc Default disable, 1.2W ~ 1.5W by models @ auto detec AC output load 10W will 279K hrs min. Telcordia TR/SR-332 (Bellcore) ; 84K hrs min. MIL-HDBK-217F (25 BAT.
VOLTAGE 12V 24V 48V 12V 24V DC CURRENT (Typ.) 25A 25A 13A 13A 7A 10W 10W 12W 10W 10W 1.2W 1.2W 1.3W 1.3W 1.5W 91% 91% 92% 92% 93% 30A*2 30A*2 30A*1 30A*1 10A*2 11 0.3Vdc ± 11 0.3Vdc ± 22 0.5Vdc ± 22 0.5Vdc ± 44 1Vdc ± 10 0.3Vdc ± 10 0.3Vdc ± 20 0.5Vdc ± 20 0.5Vdc ± 40 1Vdc ± 12.5 0.3Vdc ± 12.5 0.3Vdc ± 25 0.5Vdc ± 25 0.5Vdc ± 50 1Vdc ± 15.5 0.3Vdc ± 15.5 0.3Vdc ± 31 0.5Vdc ± 31 0.5Vdc ± 62 1Vdc ± 16.5 0.3Vdc ± 16.5 0.3Vdc ± 33 0.5Vdc ± 33 0.5Vdc ± 66 1Vdc ± 15 0.3Vdc ± 15 0.3Vdc ± 30 0.5Vdc ± 30 0.5Vdc ± 60 1Vdc ± Default setting set at 110VAC Default setting set at 230VAC Default setting set at 60Hz 0.1Hz ± Default setting set at 50Hz ± 50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W Power ON-OFF remote control by front panel dry contact connector (by RELAY) Open :
Normal work ; Short : Remote off FUNCTION Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing o Please refer to section 3.4 of installation manual OFF MODE CURRENT DRAW WORK TEMP.
-20 ~ +70 (Refer to “Derating curve”) 0.75Kg; 18pcs/ 14.5Kg/ 0.97CUFT True sine wave (THD ± 3.0% at rated input voltage WORKING HUMIDITY 20 ~ 90% RH non-condensing 186*100.5*32mm (L*W*H) BATTERY TYPES Lead Acid or li-ion By internal fuse open 3 287.5W 250W 375W 500W 2.3 Specification RATED POWER(Continuous) OVER RATED POWER(3 Min.) SURGE POWER(30 Cycles) Note.1 NON-SAVING MODE SAVING MODE Note.1 SHUTDOWN RESTART SHUTDOWN RESTART MODEL NTS-250P series PEAK POWER(10 Sec.) AC REGULATION EFFICIENCY (Typ.) FUSE (INTERNAL) ALARM ALARM OVER TEMPERATURE OVER LOAD (Typ.) REMOTE CONTROL DRY CONTACT AC VOLTAGE FREQUENCY WAVEFORM LED STATUS NO LOAD DISSPATION (Typ.) BAT.
POLARITY OUTPUT SHORT DIMENSION PACKING LOW HIGH MTBF OUTPUT DC INPUT AC OUTPUT ENVIRON- MENT OTHER INPUT PROTECTION 2 MODEL NTS-250P-112 NTS-250P-124 NTS-250P-148 NTS-250P-212 NTS-250P-224 NTS-250P-248 OUTPUT RATED POWER(Continuous) 250W OVER RATED POWER(3 Min.) 287.5W PEAK POWER(10 Sec.) 375W SURGE POWER(30 Cycles) 500W AC VOLTAGE Default setting set at 110VAC Default setting set at 230VAC 100 / 110 / 115 / 120Vac selectable by DIP S.W 200 / 220 / 230 / 240Vac selectable by DIP S.W FREQUENCY Default setting set at 60Hz±0.1Hz Default setting set at 50Hz±0.1Hz 50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W WAVEFORM Note.1 True sine wave (THD AC REGULATION ±3.0% at rated input voltage LED STATUS Please refer to section 3.4 of installation manual INPUT BAT.
VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc DC CURRENT (Typ.) 25A 13A 7A 25A 13A 7A NO LOAD DISSPATION (Typ.) NON-SAVING MODE 10W 10W 12W 10W 10W 12W SAVING MODE Default disable,≦1.2W ~ 1.5W by models @ auto detec AC output load≦10W will be changed to saving mode 1.2W 1.3W 1.5W 1.2W 1.3W 1.5W OFF MODE CURRENT DRAW EFFICIENCY (Typ.) Note.1 91% 91% 92% 92% 93% 93% BATTERY TYPES Lead Acid or li-ion PROTECTION DC INPUT FUSE (INTERNAL) 30A*2 30A*1 10A*2 30A*2 30A*1 10A*2 LOW ALARM 11±0.3Vdc 22±0.5Vdc 44±1Vdc 11±0.3Vdc 22±0.5Vdc 44±1Vdc SHUTDOWN 10±0.3Vdc 20±0.5Vdc 40±1Vdc 10±0.3Vdc 20±0.5Vdc 40±1Vdc RESTART 12.5±0.3Vdc 25±0.5Vdc 50±1Vdc 12.5±0.3Vdc 25±0.5Vdc 50±1Vdc HIGH ALARM 15.5±0.3Vdc 31±0.5Vdc 62±1Vdc 15.5±0.3Vdc 31±0.5Vdc 62±1Vdc SHUTDOWN 16.5±0.3Vdc 33±0.5Vdc 66±1Vdc 16.5±0.3Vdc 33±0.5Vdc 66±1Vdc RESTART 15±0.3Vdc 30±0.5Vdc 60±1Vdc 15±0.3Vdc 30±0.5Vdc 60±1Vdc BAT.
POLARITY By internal fuse open AC OUTPUT OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover FUNCTION REMOTE CONTROL DRY CONTACT Power ON-OFF remote control by front panel dry contact connector (by RELAY) Open : Normal work ; Short : Remote off ENVIRON- MENT WORK TEMP.
-20 ~ +70℃(Refer to “Derating curve”) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -30 ~ +70℃/ -22 ~ +158 oF, 10 ~ 95% RH non-condensing VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes OTHER MTBF 279K hrs min. Telcordia TR/SR-332 (Bellcore) ; 84K hrs min.
MIL-HDBK-217F (25℃) DIMENSION 186*100.5*32mm (L*W*H) PACKING 0.75Kg; 18pcs/ 14.5Kg/ 0.97CUFT MODEL NTS-400P-112 NTS-400P-124 NTS-400P-148 NTS-400P-212 NTS-400P-224 NTS-400P-248 OUTPUT RATED POWER(Continuous) 400W OVER RATED POWER(3 Min.) 460W PEAK POWER(10 Sec.) 600W SURGE POWER(30 Cycles) 800W AC VOLTAGE Default setting set at 110VAC Default setting set at 230VAC 100 / 110 / 115 / 120Vac selectable by DIP S.W 200 / 220 / 230 / 240Vac selectable by DIP S.W FREQUENCY Default setting set at 60Hz±0.1Hz Default setting set at 50Hz±0.1Hz 50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W WAVEFORM Note.1 True sine wave (THD AC REGULATION ±3.0% at rated input voltage LED STATUS Please refer to section 3.4 of installation manual INPUT BAT.
VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc DC CURRENT (Typ.) 40A 20A 10A 40A 20A 10A NO LOAD DISSPATION (Typ.) NON-SAVING MODE 10W 10W 12W 10W 10W 12W SAVING MODE Default disable,≦1.2W ~ 1.5W by models @ auto detec AC output load≦10W will be changed to saving mode 1.2W 1.3W 1.5W 1.2W 1.3W 1.5W OFF MODE CURRENT DRAW EFFICIENCY (Typ.) Note.1 89% 91% 91% 91% 93% 93% BATTERY TYPES Lead Acid or li-ion PROTECTION DC INPUT FUSE (INTERNAL) 40A*2 30A*2 10A*2 40A*2 30A*2 10A*2 LOW ALARM 11±0.3Vdc 22±0.5Vdc 44±1Vdc 11±0.3Vdc 22±0.5Vdc 44±1Vdc SHUTDOWN 10±0.3Vdc 20±0.5Vdc 40±1Vdc 10±0.3Vdc 20±0.5Vdc 40±1Vdc RESTART 12.5±0.3Vdc 25±0.5Vdc 50±1Vdc 12.5±0.3Vdc 25±0.5Vdc 50±1Vdc HIGH ALARM 15.5±0.3Vdc 31±0.5Vdc 62±1Vdc 15.5±0.3Vdc 31±0.5Vdc 62±1Vdc SHUTDOWN 16.5±0.3Vdc 33±0.5Vdc 66±1Vdc 16.5±0.3Vdc 33±0.5Vdc 66±1Vdc RESTART 15±0.3Vdc 30±0.5Vdc 60±1Vdc 15±0.3Vdc 30±0.5Vdc 60±1Vdc BAT.
POLARITY By internal fuse open AC OUTPUT OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover FUNCTION REMOTE CONTROL DRY CONTACT Power ON-OFF remote control by front panel dry contact connector (by RELAY) Open : Normal work ; Short : Remote off ENVIRON- MENT WORK TEMP.