SAMI G S 9 Drive Parameters 9.1 Main 10 - Control Connections 9.1.1 Group 11 - Dig/Analog Input Sel These values can only be altered when the SAMI GS is stopped.
37 Parameter Range/Unit Description 1 Run Enable 2 Ext Cont Place Sel 3 Ext 1 I/O Cont Sel 4 Ext 2 I/O Cont Sel 5 External Ref1 Sel 6 External Ref2 Sel 7 Const Speed Sel 8 Direction 9 Fault Reset Sel 10 Acc/Dec 1or2 Sel 11 Param Lock Sel Yes/DI1...DI6/Std Commu Keypad/DI1...DI6/ Std Commu Not Sel/Digital Input(s) Keypad/Std Commu Refer to page 38 same values as para.11.3 Keypad/Analogue and Digital Inputs/Std Commu Refer to page 39 Keypad/Analogue and Digital Inputs/Std Commu Refer to page 39 Not Sel/Digital Input(s) Refer to page 40 Reverse/Forward/ Request/Fast Rev Not Sel/DI1...DI6 On Stop/Std Commu Not Sel/DI1...DI6 Keypad/DI1...DI6 Run enable input External control place selection input External control reference R1 start/stop and direction input External control reference R2 start/stop and direction input External reference 1 input External reference 2 input Constant frequency input Rotation direction lock Fault/Warning/Supervision reset input Acceleration/Deceleration ramp selection Parameter lock input