omron — Руководство по эксплуатации STC HD133 HD93 Series - цветные камеры (EN)

No.16S058-01 12) AGC threshold When the difference between the current brightness and the ALC target level becomes greater than “AGC threshold + AGC tolerance”, the auto gain control starts. 13) AGC speed Please set the maximum amount of the gain change for the AGC gain control. When sets “0”, there is no limit. 14) Digital gain Please use the digital gain when the high sensitivity image output is necessary. When increasing the digital gain, the noise is also increases. Please adjust the digital gain with checking the image. B. DSP: WB The white balance settings are changeable in this window.

1) White balance mode The white balance mode is selectable from the manual white balance and the auto white balance mode. a) Manual The manual white balance mode b) AWB The auto white balance mode. Please change the white balance gain and the auto white balance control settings. 29/49 STC-HD133 Series (STC-HD133DV / STC-HD133SDI) / STC-HD93 Series (STC-HD93DV / STC-HD93SDI) Users guide