HP — svmn (EN)

ECU pan removal Figure 4-49 Removing the ECU pan Prior to this step: Remove the scanner, pods, doors, back cover, front cover, formatter; and disconnect the ECU cable. NOTE: If the fuser cables are connected, disconnect them before removing the ECU pan. 1 Remove the two screws fastened to the brackets on the sides of the pan. 2 Remove the two screws accessed through openings in the side of the black plastic printer chassis. 3 Disconnect the small solenoid connection from the back of the ECU. C4224-90962 Bottom assemblies 113