omron — Standard Specification List

● Control Circuit Terminals Specifications Relay output Selection Features Analog output Logic input Logic output Analog input Short-circuit bar SYSDRIVE JX Series SYSDRIVE MX Series SYSDRIVE RX Series SYSDRIVE Option Overview of Inverter Selection ● Mode Selector RS-485 Communication/Operator Selector (S7) Select the mode according to the option connected to the communications connector. When using the 3G3AX-OP01 supplied with the Inverter, it is available regardless of the switch condition. Emergency shutoff selector (S8) Use this selector to enable the emergency shutoff input function.

* The multi-function input terminal 3 is switched to a terminal for emergency shutoff input, and the allocation of other multi-function input terminals is also changed automatically. Do not set to ON immoderately. For details, refer to "Emergency Shutoff Input Function". Simple, Compact Inverters SYSDRIVE JX Series 17 MB MA MC MB MA MC AM FS FV FI FC S5 S4 S3 S2 S1 SC PSC P24 PC P1 AM FS FV FI FC S5 S4 S3 S2 S1 SC PSC P24 PC P1 Terminal symbol Terminal name and function Default setting Note Input signal PSC External power supply terminal for input signal (input) ...At sink logic Internal power supply output terminal for input signal (output) ...At source logic --- 24 V DC ±10% 30 mA max.

24 V DC ±10% 100 mA max. S1 Multi-function input terminals S1 to S5 Select 5 functions among the 31 functions and allocate them to from terminals S1 to S5. The terminal allocation is changed automatically when the emergency shutoff function is used. Forward/Stop Contact input Close: ON (Start) Open: OFF (Stop) Minimum ON time: 12 ms min. S2 Reverse/Stop S3 Fault reset S4 Emergency stop fault S5 Multi-step speed reference 1 SC Input signal common --- Monitor signal AM Analog frequency monitor/Analog output current monitor Analog frequency monitor Frequency reference input FS Frequency reference power supply --- 10 V DC 10 mA max.

FV Voltage frequency reference signal --- 0 to 10 V DC Input impedance 10 kΩ When installing variable resistors at FS, FV, and FC (1 to 2 kΩ) FI Current frequency reference signal --- 4 to 20 mA DC Input impedance 250 Ω FC Frequency reference common --- Output signal P1 Multi-function output terminal Select the status of the Inverter and allocate it to terminal P1. Frequency arrival signal at a constant speed 27 V DC 50 mA max. PC Output signal common --- Relay output signal MA MB MA MC Factory default relay settings Under normal operation: MA-MC Closed Under abnormal operation or power shutdown:

MA-MC Open MB MC MB MA MC Symbol Name Status Description S7 RS-485 communication/ operator selector 485 RS485 Modbus communication OPE [Default] Digital Operator (Option: 3G3AX-OP1) Symbol Name Status Description S8 Emergency shutoff selector ON Emergency shutoff input enabled * OFF [Default] Normal