SECTION 5 FAQ Q: How to select the charging mode? A: Please select the charging mode according to the battery type and capacity. We recommend that the current value should not be greater than 20% of the battery capacity value. For example, for a 20Ah battery, we recommend that the current is not greater than 4A. Q: Will TB6000Pro stop charging automatically after the battery is fully charged? A: Yes. TB6000Pro adopts 9-step smart charging. When the battery is fully charged, it will automatically stop charging without the risk of overcharging.

If you still leave the battery connected, the charger will keep monitoring the battery status and will automatically start charging when the battery voltage falls below its target threshold. Q: Can TB6000Pro charge multiple batteries simultaneously? A: Yes. Please correctly connect these batteries in series or parallel before charging. If you have questions about the connection, you can consult the battery manufacturer or contact us for help. Q: Is REPAIR mode applicable to all battery types? A: No, it can't be used for lithium batteries. However, it is applicable to all types of lead-acid batteries. Q: Why can't some batteries be used normally after repair? A: