VEDA HCT User Manual Action The attribute “Action” can be “Press” or “Release”. When “Press” is selected, data transmission will be started when the component is pressed down. When “Release” is selected, data transmission will be executed when the component is released. Data Type The “Data Type” means the type of data to be transmitted. It can be “Bit” or “Word”. Transmission words It means the number of data transmitted at one time. It can be set “Constant” or “Variable”. If set “Variable”, the register address must be designated. The maximum number of words transmitted in this software is 8192.
Source Address The “Source Address” means the first address of the data to be transmitted. The detailed can be seen in the Detailed manual/General functions/Address editor/Standard Bit Address Input or Detailed manual/General functions/Address editor/Standard Byte Address Input . Destination address The “ Destination address” means the first address of data transmission target. The detailed can be seen in the Detailed manual/General functions/Address editor/Standard Bit Address Input or Detailed manual/General functions/Address editor/Standard Byte Address Input . 4.6.1.6Recipe Transmission The “Recipe Transmission” component includes two transmission directions:
“Download recipe to PLC” and “Upload recipe from PLC”. “Download recipe to PLC” means transmitting the content of the recipe file to the address of PLC. “Upload recipe from PLC” means transmitting data from the address of PLC to the recipe file. 112