Failing Type of Checks to be Measuring Values to be DTC FMI Visible failure Possible Cause Repair action Remarks component Failure performed conditions detected 1FA TOO No reaction per- Particulate filter Check filter. HIGH ceivable by the may be blocked. NUMBER driver. OF RE- Too many filter GENER- regenerations car- ATIONS ried out. DEMAND 1FB PERMA- No reaction per- Catalytic con- Check catalytic con- NENT RI- ceivable by the verter not in- verter visually. GENER- driver. stalled or dam- ATION aged. ON TRAP PARTICLE 1FC FIRST SEN- No reaction per- Temperature Check information and SOR EX- ceivable by the sensors dam- condition of sensors. AUSTED driver.

aged or incor- GAS TEM- rectly fitted. PERATURE 21F TOO No reaction no- Actuator coil Check actuator condi- HIGH EFFI- ticeable on behalf faulty or not tion. CIENCY of the driver. within specified OF CATA- tolerance limits. LYST SYS- TEM 225 INTER- Slight power re- The control unit Check wiring and then RUPTED duction. is turned off by replace the main relay. AFTER- the general RUN switch instead of by the key (k15). Possible prob- lem in main relay or connections. 228 MAIN Slight power re- Short circuit in Check wiring between RELAY - duction. main relay or battery and ECM and SHORT relay faulty. then replace the main CIRCUIT relay.

TO GROUND DTC FMI Failing component Type of Failure Visible failure Possible Cause Repair action Checks to be performed Measuring conditions Values to be detected Remarks 1FA TOO HIGH NUMBER OF RE- GENER- ATIONS DEMAND No reaction per- ceivable by the driver. Too many filter regenerations car- ried out. Particulate filter may be blocked. Check filter. 1FB PERMA- NENT RI- GENER- ATION ON TRAP PARTICLE No reaction per- ceivable by the driver. Catalytic con- verter not in- stalled or dam- aged. Check catalytic con- verter visually. 1FC FIRST SEN- SOR EX- AUSTED GAS TEM- PERATURE No reaction per- ceivable by the driver. Temperature sensors dam- aged or incor- rectly fitted.

Check information and condition of sensors. 21F TOO HIGH EFFI- CIENCY OF CATA- LYST SYS- TEM No reaction no- ticeable on behalf of the driver. Actuator coil faulty or not within specified tolerance limits. Check actuator condi- tion. 225 INTER- RUPTED AFTER- RUN Slight power re- duction. The control unit is turned off by the general switch instead of by the key (k15). Possible prob- lem in main relay or connections. Check wiring and then replace the main relay. 228 MAIN RELAY - SHORT CIRCUIT TO GROUND Slight power re- duction. Short circuit in main relay or relay faulty. Check wiring between battery and ECM and then replace the main relay.