16/3 T RAKKER E URO 4/5 GEARBOXESZF 16 S 1620 T.D. - 2220 T.D. - 2520 T.O. Fast range Figure 2/3 Pressurized air 119422 PNEUMATIC DIAGRAM FOR PRE-SELECTION IN FAST RANGE The air fromthe services reservoir supplies the inhibitor valve (14) and the pre-selector (1) simultaneously, through the connecting pipe (15). At the same time, the valve (7) moves and opens the passage for the air between the inlet duct (11) and the duct (12) connecting with the right-hand chamber of thecylinder ofthe ksplittery (2).
On shifting the pre-selector (1) upwards (position S of fast range), the air passage between the supply pipe (15) and the double control valve (8) is closed, setting the connecting pipe (16) in communication with the outlet pipe (17). On pressing the clutch pedal, the air reaching the inhibitor valve (14) supplies the double control valve (8) through the connecting pipe (13). As a result of the air being discharged by the double control valve (8), the reaction of the spring (10) and of the springs (5) pushes the pistons (4 and 9) to the right.
The air reaching the valve (8) passes through the inlet duct (11) and, finding the passage clear, supplies the right-hand chamber of the cylinder of the ksplittery (2) through the connecting duct (12). The movement of the pistons (4 and 9) makes it possible for the valve (6) to return to its seat and discharge the air contained in the right-hand chamber of the cylinder of the ksplittery (2) into the atmosphere through the connecting duct (3). The piston ofthis cylinder,moving to the right,then drives the entire train downline, causing the fast range to be engaged. Print 603.93.641/A Revi - June 2007