Application Layer 1. This is only available in firmware V 3.05 or higher. In V 3.05, these locations are "turned off" in P762. In higher firmware, they are defaulted on. BW500/L 1. This is only available in firmware V 3.05 or higher. In V 3.05, these locations are "turned off" in P762. In higher firmware, they are defaulted on.

7ML19981AQ03 SmartLinx PROFIBUS DP – INSTRUCTION MANUAL Page 35 Description Start End Size Type batch setpoint value 18 19 2 UINT32 batch prewarn setpoint value 20 21 2 UINT32 parameter, SPA 22 22 1 integer primary index, SPA 23 23 1 integer secondary index, SPA 24 24 1 integer new value, SPA 25 26 2 UINT32 decimal place, SPA 27 27 1 integer format, SPA 28 28 1 integer read / write flag, SPA 29 29 1 1/0 word order 30 30 1 1/0 Instrument Status 21 31 31 1 bitmapped batch total1 32 33 2 UINT32 Description Start End Size Type instrument status 1 0 0 1 bitmapped rate 1 2 2 UINT32 load 3 4 2 UINT32 speed 5 6 2 UINT32 total 1 7 8 2 UINT32 total 2 9 10 2 UINT32 relay status 11 11 1 bitmapped discrete input status 12 12 1 bitmapped parameter, SPA 13 13 1 integer primary index, SPA 14 14 1 integer secondary index, SPA 15 15 1 integer new value, SPA 16 17 2 UINT32 decimal place, SPA 18 18 1 integer format, SPA 19 19 1 integer read / write flag, SPA 20 20 1 integer word order 21 21 1 integer Instrument Status 21 22 22 1 bitmapped