Example 1 If you want only rate, load, and batch prewarn, the chart is: Appendix A The input data block (Read block) is now 6 words in size (12 bytes) and the Word numbers have shifted to a lower value: New Read Block Data Map Original Read Block Data Map for Mass Dynamic Products 7ML19981AQ03 SmartLinx PROFIBUS DP – INSTRUCTION MANUAL Page 55 word order 14 1 status 2 15 1 batch total 16 2 Total words:
Name of area P762 Point value Memory size for Read block per value value * memory size status 1 0 1 0 rate 2 1 2 2 load 3 1 2 2 speed 4 0 2 0 total 5 0 4 0 relay status 6 0 1 0 DI status 7 0 1 0 SPA 8 0 8 0 command control 9 0 0 0 multispan 10 0 1 0 PID 11 0 4 0 batch 12 0 2 0 batch prewarn 13 1 2 2 word order 14 0 1 0 status 2 15 0 1 0 batch total 16 0 2 0 total words: 6 Word Description 0-1 rate 2-3 load 4-5 batch prewarn Description Start End Size Type instrument status 0 0 1 bitmapped rate 1 2 2 UINT32 load 3 4 2 UINT32 speed 5 6 2 UINT32 total 1 7 8 2 UINT32