1. For firmware V 3.05, the default is o. For all higher versions, the default is 1. Module Identification Parameters P794 and P795 are used together to identify the module type and protocol used. P794 SmartLinx Module Type Identifies the module used. P795 SmartLinx Protocol Identifies the protocol used: the value varies according to the module, and whether it is a type 1 or type 2.
Communicatons Set-up 7ML19981BH02 SmartLinx DeviceNet – Instruction Manual Page 15 Milltronics BW 500 and Milltronics SF 500 10 0 = No MultiSpan 1 1=Yes 11 PID 1 0 = No 1=Yes 12 0 = No Batch 1 1=Yes 13 Batch Prewarn 1 0 = No 1=Yes 14 0 = No Word Order 1 1=Yes 15 Status 2 11 0 = No 1=Yes 16 0 = No Batch Total 11 1=Yes Value Module 0 No module present 1 Anybus DT module 2 Anybus S module Siemens Milltronics Instrument Card P794 value P795 value ER-500 BW500 / SF500 MultiRanger 100 / 200 AB RIO 1 72 Profibus DP 2 1 DeviceNet 2 37 AiRanger / SITRANS LU AB RIO 1 72 Profibus DP 1 24 DeviceNet 1 34 Modbus RTU 1 57 Modem Card 1 133