Data Map 2: EnviroRanger ERS 500, MultiRanger 100/200, HydroRanger 200 Application Layer Note: Refer to the PLC documentation on how to program "reads and writes" in your PLC. Write Block Word 0: Point-on-Priority Bits 00-09 set the priority status of corresponding indexed points 1 to 10.
bit status 0 = normal 1 = priority 7ML19981BH02 SmartLinx DeviceNet – INSTRUCTION MANUAL Page 27 Word Description Access Data Type 0 measurement point on priority direct bitmapped 1 parameter number MPA integer 2 secondary index (mark) integer 3 decimal place integer 4 format 0/1 5 parameter number integer 6 primary index (point) integer 7 secondary index (mark) integer 8 new value SPA integer 9 decimal place integer 10 format 0/1 11 read/write flag 0/1 12 operating mode direct 0/1 bit 09 08 07 06 05 04 03 02 01 00 index 10 9 8 7 6 5 4 3 2 1