Bit 12: Write Privileges Indicates whether the PLC can write parameters/commands to the product. This is controlled by parameter P799. Application Layer P799 = 1 PLC may change the Siemens Milltronics SmartLinx instrument’s parameters P799 = 0 PLC can only read. Bit 13: Configuration Status Indicates whether the unit is configured (all required parameters entered). Bit 14: Program Mode Indicates program (calibration) mode: 0 = PROGRAM mode 1 = RUN mode Bit 15: Totalizing Status Indicates whether the unit is totalizing. Words 1, 2: Rate Contains the current rate reading in engineering units. (See the Milltronics BW500 manual for a full description of this reading.) Words 3, 4:

Load Contains the current load reading in engineering units. (See the Milltronics BW500 manual for a full description of this reading.) Words 5, 6: Speed Contains the current speed reading in engineering units. (See the Milltronics BW500 manual for a full description of this reading.) Words 7, 8: Total 1 1 Contains the current value for totalizer 1 in engineering units. (See the Milltronics BW500 manual for a full description of this reading.) Words 9, 10: Total 2 1 Contains the current value for totalizer 2 in engineering units. (See the Milltronics BW500 manual for a full description of this reading.) 1.

The number of fixed decimal places for this value is controlled by P634 primary indexes 1 and 2. The default setting is 3. (See page 16 for details.) 7ML19981BH02 SmartLinx DeviceNet – INSTRUCTION MANUAL Page 39