HP — Separation discharge high-voltage converter assemblies

Separation discharge high-voltage converter assemblies The separation discharge high-voltage converter assemblies are located in the bottom right corner of the rear of the printer. Removing separation discharge high-voltage converter PCA 1 Remove the rear cover (see page 243). 2 Remove the formatter board and formatter pan (pages 254, 272). 3 Unplug three connectors from the PCA (callout 1). 2 1 2 2 Figure 146. Separation discharge high-voltage converter 4 Release one cable stay. 5 Remove two screws (callout 2). 6 Lift the PCA up and off. Removing separation discharge high-voltage converter 1 Remove the high-voltage converter 3 PCA (see page 295). 2 Unplug one connector.

3 Pull the converter toward you and lift out. EN Rear assemblies 295