Single-axis controllers Wiring Devices in the range 145 ... 695 A (75 ... 400 kW) 4 4.6 4.6.5 External brake resistor DC bus Tip! Now mount the barrier between mains input and power terminals, if had been removed to have more free space for wiring. Mains 4.6-27 EDS94SPP101 EN 3.1-04/2007 Terminal X105 Labelling Description Rb1 Rb2 Terminal data Max. conductor cross-section Tightening torque Screw drive [mm2] [AWG] [Nm] [lb-in] 95 000 14 124 Terminal X100 Labelling Description +UG -UG Alternative option for DC-bus voltage connection (compatible to 9300 series). Terminal data Max. conductor cross-section Tightening torque Screw drive [mm2] [AWG] [Nm] [lb-in] Device size 8S:
Flexible With wire end ferrule 95 000 14 124 Inbus 5 Terminal X100 Marking Description SSP94KL0X8 L1 L2 L3 Connection of the mains phases L1, L2, L3 Connection for the PE conductor on the supply side with M8 ring cable lug Terminal data Max. conductor cross-section Tightening torque Screw drive [mm2] [AWG] [Nm] [lb-in] Device size 8S: Flexible With wire end ferrule 95 000 14 124 Inbus 5 M8 ring cable lug 95 000 9.5 84 WAF 13